Hotline
0755-27500078

Industry news

Industry news

Ten faults and maintenance methods of RO reverse osmosis purified water equipment

2022-05-26 15:50:04   Visit:910

Ten faults and maintenance methods of RO reverse osmosis purified water equipment

1、 The switch is on, but the device does not start:

1. Electrical circuit failure, such as broken fuse and wire falling off

2. The thermal protection element is not reset after protection

resolvent:

1. The waterway is under voltage, check the fuse and check the wiring everywhere

2. Reset the thermal protection element

3. Check the waterway and ensure the water supply pressure

2、 After the equipment is started, the water inlet solenoid valve is not opened:

1. The wiring falls off

2. Internal mechanical failure of solenoid valve

3. Solenoid valve coil is broken

resolvent:

1. Check the circuit

2. Disassemble solenoid valve for maintenance

3. Repair or replace the coil

3、 The pump operates but fails to reach the rated pressure and flow:

1. Pump reverse

2. The filter element of the security filter is dirty

3. There is air in the pump

4. Open the flushing solenoid valve

Solution:

1. Rewire

2. Clean or replace the filter element

3. Remove the air in the pump

4. adjust the pressure after flushing

4、 When the system pressure increases, the pump noise is loud

1. Insufficient raw water flow

2. Unstable raw water flow

Solution:

1. Check the raw water pump and pipeline

2. Check the raw water pump and pipeline and check whether there is leakage in the pipeline

5、 The solenoid valve is not closed after flushing

1. Solenoid valve control element and circuit failure

2. Mechanical failure of solenoid valve

resolvent:

1. Check or replace components and circuits

2. Disassemble, repair or replace the solenoid valve

Vi. undervoltage shutdown

1. Insufficient raw water supply

2. The filter element of the security filter is blocked

3. Under pressure caused by improper pressure adjustment and automatic flushing

resolvent:

1. Check whether the raw water pump and pretreatment system are working

2. Clean and replace the filter element 3 Adjust the system pressure to the best state and maintain the filtered pressure above 20psi

7、 The concentrated water pressure cannot reach the rated value

1. Pipeline leakage

2. Flushing solenoid valves are not fully closed

3. Leakage of recovery system

resolvent:

1. Check and repair the pipeline

2. Check and replace the flushing solenoid valve

3. Check and repair the recycling system

8、 The pressure is sufficient, but the pressure display is not in place

1. Foreign matters in the pressure gauge hose are blocked

2. There is air in the hose

3. Pressure gauge failure

resolvent:

1. Check and dredge the pipeline

2. Remove air

3. Replace the pressure gauge

9、 Deterioration of water quality

1. Membrane pollution and scaling

2. Aging and failure of membrane junction seal

resolvent:

1. Carry out chemical cleaning according to technical requirements

2. Replace O-ring

3. Replace the membrane

10、 Production decline

1. For membrane pollution and scaling, chemical cleaning shall be carried out according to the technical requirements

2. The water temperature change shall be recalculated according to the actual water temperature to determine the water production.